AUXILIARY RELAYS JRV 151

OVERVIEW

    Features

  • Electromechanical design
  • Plug-in construction
  • Standardised contact arrangement
  • Self or hand reset contacts
  • Protective transparent cover for the element
  • Compact panel mounting case

Application:

switching functions in protection and control circuits contact multiplication.

AUXILIARY RELAYS JRV 151

Description

The auxiliary relays are electromechanical, attracted armature type, used in control and alarm circuits. There relays are designed as plug-in elements with the plug-in base having 16 terminals per element. Each element is enclosed in a dust proof moulded, transparent, polycarbonate cover. There is no hard wiring

between the relay element and the rear terminals on the base. This results in a compact rugged and reliable design. Radio metal is used for the magnetic components such as the armature, the core and the yoke of the auxiliary relay to ensure good electrical performance. The contacts are made from phosphor bronze and are nickel plated. The contact tips are of pure silver. The use of these materials ensures very good contact performance.

 

SPECIFICATIONS

Ratings:

Rated voltage

:

24,30, 48, 110, 220 V DC or 63.5, 110 or
230v, 50Hz AC

Operating range

:

75-120% of rated voltage for DC relays
80-115% of rated voltage for AC relays

Reset value

:

Above 10% of the rated voiltage

Burden

:

4 watts(maximum) at rated voltage

Operating time

:

Less than 20 ms at rated voltage(nominal)

Reset time

:

less than 10 ms

Operation indicator

:

a) self reset flag or
b) hand reset flag or
c) hand reset reverse flag for AC/DC fail indication or
d) no flag

     

Contact Ratings

Make & Carry continous
(AC – DC)

:

2500 VA with maxima of 5 A and maxima of 660 V AC
2500 W with maxima of 5A and maxima of 660 V DC

Make & Carry for 3s
(AC – DC)

:

7500 VA with maxima of 30 A and maxima of 660 V AC
7500 W with maxima of 30A and maxima of 660 V DC

Break (AC-DC)

:

2500VA with maxima of 5 A and maxima of 660V AC
100W (resistive) 50W (inductive) with maxima of 5A and maxima of 250V DC

 

   
 

Mechanical Design:

 

Contacts Durability

Unloaded contact

:

1,000,000 Operations

Loaded contact

:

100,000 Operations

     

Insulation:

  1. 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec.
    Between all terminals and cases.
  2. 1 KV RMS, 50Hz. For 1 minute across open contacts as per IEC 60255
 
 

Operating temperature

-10 deg. To +55 deg.C

 
 
 
 