ELECTRICAL RESET AUXILIARY RELAY JRV 192

OVERVIEW

Application:

The relay is intended for use in the applications requiring.

  1. Increased current-carrying or interrupting capability in a contact ( low current contact energizes the coil to close the high current contact)
  2. Circuit isolation.
  3. Contact conversion ( for example, from a normally open to normally closed condition), or
  4. Contact multiplication ( from one contact input to two contact output)lectromechanical design

ELECTRICAL RESET AUXILIARY RELAY JRV 192

Principle of Operation:

The applied input voltage creates the magnetic field on the armature and intend to operate or reset the relay.

 

SPECIFICATIONS

Ratings:

Rated voltage

:

110, 220V, 250V DC & 230V AC

Operated range

:

75 – 120% of rated voltage

Reset range

:

75 – 120% of rated voltage

Operating time

:

Less than 20 ms at rated voltage for series coils
Less than 20 ms for coil A & less than 40 ms for
coil B at rated voltage – for parallel coils.

Reset time

:

Less than 30 ms at rated voltage

Operating indicator

:

Mechanical flag, electrically reset

Contacts

:

4 N/O + 4 N/C or 6 N/O + 2 N/C

     

Burden:

Operate Coil

:

8 Watts (maximum) at rated voltage

Reset Coil

:

20 Watts (maximum) at rated voltage

     

Accuracy

Operating value

:

± 5%

Operating time

:

± 5% or ± 30msec

Instantaneous time

:

Less than 40msec.

     
 

Contact Ratings

Make & Carry continous
(AC – DC)

:

2500 VA with maxima of 5 A and maxima of 660 V AC
2500 W with maxima of 5A and maxima of 660 V DC

Make & Carry for 3s
(AC – DC)

:

7500 VA with maxima of 30 A and maxima of 660V AC
7500 W with maxima of 30A and maxima of 660 V DC

Break (AC-DC)

:

2500VA with maxima of 5 A and maxima of 660V AC
100W (resistive) 50W (inductive) with maxima of 5A and maxima of 250V DC

 

   
 
 

Contacts Durability

Unloaded contact

:

1,000,000 Operations

Loaded contact

:

100,000 Operations

     

Insulation:

  1. 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec.
    Between all terminals and cases.
  2. 1KV RMS, 50 Hz for 1 minute across open contacts
 
 

Mechanical Design

Weight

:

2Kg. (approx)

Case size

:

144sq mm, depth 125mm

Installation

:

Flush mounting

Panel cutout

:

138mm x 138mm

     

Standard Compliance

Accuracy test

:

IEC 61810-7

Insulation test

:

IEC 60255-5

     
 
 

ELECTRICAL RESET AUXILIARY RELAY JRV 192

DOWNLOADS

ELECTRICAL RESET AUXILIARY RELAY JRV 192

Catalogues:

DOWNLOAD

Operating Manual:

DOWNLOAD

 

ELECTRICAL RESET AUXILIARY RELAY JRV 192

 

ORDERING INFO.

Ordering Information:

Relay type

:

JRV 192

Auxiliary Supply

:

110V DC
220V DC
250V DC
230V AC

     
 

ELECTRICAL RESET AUXILIARY RELAY JRV 192

 

A WebSpotLight creation by Netsoft.