Local Breaker Back Up Protection Relay
₹23,595.00
Product Code: JRC 154
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 4469 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Wide OC setting range
- Wide time setting range
- Fast reset time
- High drop-off / pickup ratio
Application
JRC 154 local breaker backup relay, is used to check the operation of distribution end circuit breakers and to trip the feeder end circuit breaker if the distribution end circuit breaker fails to trip.
Principle of Operation
If a fault occurs at the distribution end and the respective protective relay operates but the corresponding CB fails to operate then the system may have
to face catastrophic consequences. JRC-154 is a instantaneous and definite time over current relay that also monitors the non-potential contacts of the
downstream protective relays. The relay is designed to trip the feeder end CB if the protective relay at the distribution end operates but its corresponding CB fails
to operate.
Ratings
Settings
OVER LOAD RATINGS
Burden
Operating Time
ACCURACY
Primary current rating :
1A / 5A
Frequency :
50Hz
Auxiliary Supply :
1) 20 to 60V DC
2) 75 to 150V DC / AC
3) 175 to 300V DC / 185 to 250V AC
2) 75 to 150V DC / AC
3) 175 to 300V DC / 185 to 250V AC
Over Current :
5 to 200% in steps of 5%
Definite time :
50 ms to 1.25 sec in steps of 10 ms.
AC current input :
2 times rated continuously
20 times Rated for 3s
20 times Rated for 3s
AC current input :
0.2VA Per phase (at Rated 5A)
0.05VA per Phase (at Rated 1A)
0.05VA per Phase (at Rated 1A)
Aux. Supply :
Less than 5W (Non Operated)
Less than 10W (Operated)
Less than 10W (Operated)
Instantaneous operating time :
Less than 10 ms.
Current protection :
±5%
Operating Time :
±5%
Contact Ratings
Contact Durability
Insulation
Rating :
10A at 24V DC/230V AC
Unloaded contact :
10,000 Operations
Loaded contact :
20,000 Operations
- 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec .
Between all terminals and earth - 2. 1 KV RMS, 50 Hz for 1 minute across open contacts as per IEC 60255-5
Weight :
Approx. 2500 gms
Case Size :
144sq mm, depth 232mm
Installation :
Flush mounting
Panel cutout :
138mm x 138mm
TERMINAL DIAGRAM
Ordering Information
Current rating :
1A or 5A
Auxiliary Supply :
1) 20-60V DC
2) 75 – 150V AC / DC
3)175 – 300V DC/185 – 250V AC
2) 75 – 150V AC / DC
3)175 – 300V DC/185 – 250V AC