Two Shot, Auto Reclose Relay
₹9,938.50
Product Code: JRV 144
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 4585 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Built in Auto / Manual selection facility
- Number of shots selectable
- High accuracy and stability
APPLICATION
The auto reclose function is normally used in feeder protection relays that are protecting an overhead line. Most of the overhead line faults are temporary in nature. Upto 85% can be cleared by using the auto reclose function.
Design and Construction
The relay receives the fault initiation from the protection relay and that triggers the auto reclose function. After tripping the circuit breaker(CB), the Auto reclose function can reclose the CB. Normally, the first reclose (or shot) is so short in time that consumer cannot notice anything. However the fault is cleared and the feeder will continue in normal service.
Even though the basic principle of Auto reclose is simple, there are a lot of different timers and parameters that have to be set.
Even though the basic principle of Auto reclose is simple, there are a lot of different timers and parameters that have to be set.
Ratings
Settings
Burden
Accuracy
Number of shots :
1shot or 2shot
Auxiliary supply :
20 to 60VDC
75 to 150VDC/AC
175 to 300VDC
185 to 250 VAC
75 to 150VDC/AC
175 to 300VDC
185 to 250 VAC
1 – SHOT STD
Reclaim time :
5 – 80s in steps of 5s
Dead time :
3 – 10s in steps of 1s
2 – SHOT STD
Reclaim time :
20 – 320s in steps of 20s
Dead time 1 :
10s – 80s in steps of 10s
Dead time 2 :
30s – 170s in steps of 20s
Aux. Supply :
Less than 5W( Non operated)
Less than 7W(Operated)
Less than 7W(Operated)
Operating Time :
+/- 5% or +/- 30ms whichever is higher
Contact Ratings
Contact Durability
Insulation
Standard Compliance
Lockout Relay & Reclose Relay :
10A at 24V DC/230V AC
Loaded conatct :
10,000 operations min
Unloaded contact :
100,000 operations min
- 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1s . Between all terminals and cases.
- 1KV RMS, 50 Hz for 1 minute across open contacts
Weight :
2500 gms. (approx)
Case Size :
144sq mm, depth 232mm
Installation :
Flush mounting
Panel cutout :
138mm X 138mm
Accuracy Test :
IEC 60255-3
Insulation Test :
IEC 60255-5
TERMINAL DIAGRAM
Ordering Information
Relay rating Type :
JRV 144(1 Shot Standard)
Aux. Supply :
20 to 60V DC
75 to 150V AC/DC or
175 to 300V DC(185 to 250V AC)
75 to 150V AC/DC or
175 to 300V DC(185 to 250V AC)