Four Pole, Non-Directional, 3 O/C + 1 E/F Relay
₹23,595.00
Product Code: JRC 054
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 4694 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Programmable time current characteristics
- Choice of four IDMT curves
- Draw out case
- Wide range auxiliary supply
- Low burden
DESIGN AND OPERATION
The relay measures the line current from each of the phases and if exceeds the set operating current, then relay extends a trip signal after the operating time. The relays operating time is determined by selecting one of the four inverse time current characteristics. The relay has facility to active / inhibit the high set protection feature. The relay output contacts are self reset type. Relay operation without any fault current is determinated by trip test facility
Ratings
SETTINGS
OVER LOAD RATING
BURDEN
Current rating :
1A / 5A
Aux. Supply :
1) 20 to 60V DC
2) 75 to 150V AC / DC
3) 175 to 300V DC / 185 to 250V AC
2) 75 to 150V AC / DC
3) 175 to 300V DC / 185 to 250V AC
Operating characteristics :
1) 3.0s Normal Inverse
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
5) 0.6s Extermely Inverse (Optional)
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
5) 0.6s Extermely Inverse (Optional)
Phase Overcurrent :
50% to 200% in steps of 10% or
20% to 140% in steps of 10%
20% to 140% in steps of 10%
Earth fault (IDMT) :
5 to 80% in steps of 5%
TMS :
0.1 to 1.0 in steps of 0.01(Seperate for O/C & E/F)
Current input :
2 times rated continuous
20 times rated for 3s
40 times of rated for 1s
20 times rated for 3s
40 times of rated for 1s
Current input :
0.2VA at rated 5A
0.05VA at rated 1A
0.05VA at rated 1A
Auxiliary supply :
Less than 8W (Non operated)
Less than 10W (Operated)
Less than 10W (Operated)
ACCURACY
CONTACT RATINGS
CONTACT DURABILITY
INSULATION
MECHANICAL DESIGN
Operating value :
105% to 120% of seting
Drop-off / pick-up :
Between 80% to 95%
Operating Time :
±5% or ±30ms whichever is higher
Reset Time :
160ms to 180ms
Trip / Alarm :
10A at 24V DC / 230V AC
Loaded contact :
10,000 operations min.
Unloaded contact :
20,000 operations min.
- 2KV RMS, 50 Hz for 1 minute/ 2.5KV FOR 1 sec.
Between all terminals and cases - 1KV RMS, 50 Hz for 1 minute across open terminals
Accuracy test :
IEC 60255-151
Insulation test :
IEC 60255-27
Weight :
Approx. 2500 gms
Size :
144sq mm, depth 232mm
Installation :
Flush mounting
Panel cutout :
138mm x 138mm
TERMINAL DIAGRAM
Ordering Information
Relay type :
JRC 054
Low set (IDMT) 3 O/C + 1 E/F
Low set (IDMT) 3 O/C + 1 E/F
Current rating :
1A or 5A
Aux. Supply :
20 to 60V DC
75 to 150V AC/DC
175 to 300V DC/ 185 to 250V AC
75 to 150V AC/DC
175 to 300V DC/ 185 to 250V AC