Three Pole, Numerical ,NON-DIRECTIONAL, 3 O/C OR 2 O/C+1 E/F Relay With Inst.Highset
₹32,157.84
Product Code: JNC 066/JNC 066P
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 5358 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Choice of four curves and definite time
- History of 5 latest faults
- Self supervision facility
- Wide setting ranges
- Draw -out case
Application
The relay provides time graded phase and earth fault
protection of Generators, Transformers, Feeder, capacitors etc.,
PRINCIPLE OF OPERATION
The relay provides over current protection for power systems. Relay operating time is determined by selecting definite time characteristics or one of the four inverse time characteristics i.e. (3s normal inverse, 1.3s normal inverse, 1.5s very inverse and 0.8s extremely inverse). The relay measures the current from each phases and if it exceeds the set threshold,the relay extends a trip signal after an operating time as determined by the selected curve.
Ratings
SETTINGS
OVER LOAD RATING
BURDEN
Current rating ( In ) :
1A / 5A
Aux. Supply :
1) 20 to 60V DC
2) 75 to 150V AC / DC
3) 175 to 300V DC / 185 to 250V AC
2) 75 to 150V AC / DC
3) 175 to 300V DC / 185 to 250V AC
Operating characteristics :
1) 3.0s Normal Inverse
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
5) Definite time
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
5) Definite time
Phase O/c (IDMT) :
50 to 200% in steps of 5%
Definite time :
0.1 to 25.0 Sec in steps of 0.1s
Earth fault (IDMT) :
5 to 50% in steps of 1%
10 to 80% in steps of 1%
10 to 80% in steps of 1%
TMS :
0.02 to 1.0 in steps of 0.01 (separate for O/C & E/F)
Reset Mode:
Hand / Self Reset (Programmable , Common for Phase
& E/F)
Current input :
2 times rated continuous
: 20 times rated for 3s
: 20 times rated for 3s
Current input :
0.2 VA per phase (rated 5A)
0.05VA per phase (rated 1A)
0.05VA per phase (rated 1A)
Aux. Supply :
Less than 8W (Non operated)
Less than 10W (Operated)
Less than 10W (Operated)
ACCURACY
CONTACT RATINGS
CONTACT DURABILITY
INSULATION
Operating value :
105% to 120% of seting
Drop-off / pick-up :
Between 80% to 95%
Operating Time :
±5% or ±30ms whichever is higher
High set operating value :
±5% or ±30ms whichever is higher
High set operating time :
Less than 30ms @ 2 times current setting
Reset Time :
160ms to 180ms
TRIP / ALARM / Self Supervision
10A at 24V DC / 230V AC
Loaded contact
10,000 operations min.
Unloaded contact
20,000 operations min.
- 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec . Between all terminals and earth.
- 1KV RMS, 50 Hz for 1 minute across open contacts
Weight Case
2500 gms. (approx),
Size
144sq mm, depth 232mm
Installation
Flush mounting
Panel cutout
138mm x 138mm
TERMINAL DIAGRAM
Ordering Information
Relay type:
JNC 066 (2O/C + E/F)
JNC 066P (3O/C)
JNC 066P (3O/C)
Specify E/F :
5 - 50% or 10 - 80%
Current rating :
1A or 5A
Aux. Supply :
20 to 60V DC or
75 to 150V AC/ DC or
175 to 300V DC / 185 to 250V AC
75 to 150V AC/ DC or
175 to 300V DC / 185 to 250V AC