Single Pole, AC Over Voltage Relay
₹10,948.08
Product Code: JRV 042
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 4971 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Instantaneous/Definite time selection
- Wide auxiliary supply
APPLICATION
Over Voltage Relay is used for protection of motors, generators and capacitor banks, feeder etc.
PRINCIPLE OF OPERATION
The Relay, JRV 042, provides Over voltage protection for power systems. The Relay operating time is determined by the set definite time. The relay measures the voltage from input PT and if it exceeds above the set threshold, the relay extends a trip signal after the operating time, which is determined by set definite time. The relay output contacts are self reset type. The TEST button facilitates testing of relay contacts for the trip and alarm circuits.
TECHNICAL DATA RATING
SETTINGS
OVER LOAD RATINGS
Burden
Accuracy
Voltage rating :
110V / 230V /415 AC
Auxiliary supply :
20 to 60V DC
75 to 150V DC
175 to 300V DC/185-250V AC
75 to 150V DC
175 to 300V DC/185-250V AC
Voltage setting :
105 to 170% in steps of 5%
Definite time :
0 to 25s in steps of0.1s
Voltage input :
2 times Rated continuous
Input voltage :
Less than 2VA at Rated
Less than 0.5VA at rated 5A
Less than 0.5VA at rated 5A
Auxiliary supply :
Less than 2W (Non Operated)
Less than 5W (Operated)
Less than 5W (Operated)
Operating value :
+/- 5%
Operating time :
+/- 5% or +/- 20ms
Instantaneous Time :
Less than 40ms
Contact Ratings
Contact Durability
Insulation
Mechanical Design
Rating :
10A at 24V DC/230V AC
Loaded contact :
10,000 operations
Unloaded contact :
20,000 operations
- 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec .
Between all terminals and cases - 1 KV RMS, 50 Hz for 1 minute across open contacts
Accuracy test :
IEC 60255-151
Insulation test :
IEC 60255-27
Weight :
Approx. 1500 gms
Case size :
144 sq mm with depth of 117 mm
Installation :
Flush mounting
Panel cutout :
138 X 138 mm
TERMINAL DIAGRAM
Ordering Information
Voltage rating :
110V / 230V / 415V AC
Relay Type :
JRV 042 (AC UVR)
Auxiliary supply :
20 to 60V DC
75 to 150V DC
175 to 300V DC/185-250V AC
75 to 150V DC
175 to 300V DC/185-250V AC