Single Pole, Directional Over Current Or Earth Fault Relay With High Set Feature
₹22,165.00
Product Code: JRP 012 / 22
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 5407 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Programmable time current characteristics
- Choice of four curves
- Selectable characteristic angle
- Programmable directional element / Non-directional element
- Draw - out case
Application
The relay provides time graded phase and earth fault
protection of Parallel transformers, Transformer feeders,
Parallel feeders, ring main system etc.,
PRINCIPLE OF OPERATION
The relay measures the line current from each of the phases or earth fault and if it exceeds the
set threshold, then relay extends a trip signal after an operating time. The relay's operating time
is determined by selecting one of the four inverse time characteristics. The relay has facility to
active / inhibit the high set protection feature. The relay output contacts are self reset . Relay
operation without any fault current is determined by trip test facility
Ratings
SETTINGS
Characteristics Angle setting
OVER LOAD RATINGS
BURDEN
Current rating ( In ) :
1A / 5A
Voltage rating :
110V, 50Hz For Phase
63.5V, 50Hz For E/F
63.5V, 50Hz For E/F
Aux. Supply :
1) 20 to 60V DC
2) 75 to 150V AC / DC
3) 175 to 300V DC
185 to 250V AC
2) 75 to 150V AC / DC
3) 175 to 300V DC
185 to 250V AC
Operating characteristics:
1) 3.Os Normal Inverse
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
Phase O/c (IDMT):
50 to 200% in steps of 10%
Earth fault (IDMT):
5 to 80% in steps of 5%
10 to 80% in steps of 1%
10 to 80% in steps of 1%
TMS:
0.1 to 1.0 in steps of 0.01
Phase Hi-set:
200 to 3200% in steps of 200%
Earth fault Hi-set:
50 to 800% in steps of 50%
O/C setting :
Lead 30°
Lead 45°
Lead 60°
Lead 45°
Lead 60°
E/F setting :
Lag 12.5°
Lag 30°
Lag 45°
Lag 30°
Lag 45°
Current input :
2 times rated continuous
20 times rated for 3s
20 times rated for 3s
Current input :
0.2 VA per phase (rated 5A)
0.05VA per phase (rated IA)
0.05VA per phase (rated IA)
Auxiliary supply :
Less than 8W (Non operated)
Less than 10W (Operated)
Less than 10W (Operated)
ACCURACY
CONTACT RATINGS
Contact Durability
Insulation
STANDARD COMPLIANCE
Operating value :
105% to 120% of setting
Drop-off / pick-up :
Between 80% to 95%
Operating Time :
±5% or ±30ms whichever is higher
High set operating value :
±5% or ±30ms whichever is higher
Phase angle :
±9° of the operating angle
High set operating time :
Less than 30ms @ 2 times current setting
Reset Time :
160ms to 180ms
Relay rating :
10A at 24V DC/230V AC
Loaded contact :
10,000 operations min.
Unloaded contacts :
20,000 operations min.
- 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec .
Between all terminals and earth. - 1KV RMS, 50 Hz for 1 minute across open contacts.
Weight :
2500 gms. (approx),
Case Size :
144sq mm, depth 232mm
Installation :
Flush mounting
Panel cutout :
138mm x 138mm
Accuracy Test :
IEC 60255-3
Insulation Test :
IEC 60255-5
TERMINAL DIAGRAM
Ordering Information
Relay rating type:
JRP 012 (O/c with hiset relay)
JRP 022 (E/F with hiset relay)
JRP 022 (E/F with hiset relay)
Current rating :
1A or 5A
Aux. Supply :
20 to 60V DC or
75 to 150V AC/ DC or
175 to 300V DC / 185 to 250V AC
75 to 150V AC/ DC or
175 to 300V DC / 185 to 250V AC