Single Pole, Neutral Displacement Relay
₹8,008.00
Product Code: JRV 962
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 4943 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Instantaneous/ Definite time selection
- Wide setting range
- Wide auxiliary range
APPLICATION
Earth fault protection in transformer generator motor and capacitor banks.
PRINCIPLE OF OPERATION
The sensing Voltage is applied to the input terminals of the relay.
The applied voltage is amplified
and fed to a Voltage Comparator. Output of the comparator is applied to the processor. The
Program residing in the CPU performs the function of measurement and extends a trip signal
after the set time delay is reached. The Relay contacts are self reset type and indications are
latched. The RESET button provided on the front of relay to clear these latched indications. The
TEST button is provided to test the relay contacts for the trip and alarm circuits.
Ratings
Settings
Over Load Ratings
Burden
Accuracy
Voltage rating :
63.5V / 110V AC
Auxiliary Supply :
30V DC (20V to 60V DC)
80 to 260V AC / DC
80 to 260V AC / DC
Voltage setting :
2.5% to 80% in steps of 2.5%
Definite time :
0.1 to 25sec in steps of 0.1sec
Voltage input :
2 times rated continuous
Voltage input :
Less than 2VA at rated
Auxiliary supply :
Less than 2W( Non operated)
Less than 5W(Operated)
Less than 5W(Operated)
Operating value :
+/- 5%
Operating time :
+/- 5% or +/- 30msec
Instantaneous time :
Less than 40msec
Contact Ratings
Contact Durability
MECHANICAL DESIGN
STANDARD COMPLIANCE
contacts 1&2 :
5A at 24V DC / 230V AC
Unloaded contact :
20,000 operations
Loaded contact :
10,000 operations
Weight:
Approx. 500 gms
Case Size :
96 mm sq, depth 105mm
Installation :
Flush mounting
Panel cutout :
92x92 mm
Accuracy Test :
ICC 60255-151
Insulation Test :
ICC 60255-27
TERMINAL DIAGRAM
Ordering Information
Voltage rating :
63.5V / 110V AC
Relay Type :
JRV 962
Auxiliary Supply :
30VDC
80 to 260V AC / DC
80 to 260V AC / DC