NUMERICAL CHECK SYNCHRONIZING RELAY
₹49,478.00
Product Code: JNF 060
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 6748 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Programmable bus voltages
- Programmable bus frequencies
- Programmable phase angle difference between two buses
- Dead bus Active/Inhibit feature
- History of 5 latest relay closing details
- Self Supervision facility
Application
JNF 060 is used in power systems in order to prevent interconnection of badly synchronized supplies. Synchro check relay is used in series with a breaker closing circuit and automates the operation of synchronizing two buses.
Principle of Operation
JNF 060 monitors voltage, frequency and phase angle difference of both the buses. If “dead bus” feature is Inhibit and If the voltage, frequency and the phase angle differences are within the pre-set limits, then the N/O contacts of the relay operates indicating synchronization of the buses else the relay does not operate.
If “dead bus” feature is Active and if the status of one of the buses (bus-1) is programmed as “dead bus” and the other (bus-2) is considered normal, Then, the relay operates if the voltage on bus-2 is greater than 80% of the rated voltage and the voltage on bus-1 is lesser than a programmable value (30%-80% of the rated voltage).
Output relay can be operated either in continuous mode or pulse mode. In continuous mode, the relay N/O contacts operate after a programmable delay and will remain in that condition until either a synchro check fails or h/w or power on reset occurs. In the pulse mode, the relay N/O contacts operate for a short while and gets released after a fixed delay of 150msec.
If “dead bus” feature is Active and if the status of one of the buses (bus-1) is programmed as “dead bus” and the other (bus-2) is considered normal, Then, the relay operates if the voltage on bus-2 is greater than 80% of the rated voltage and the voltage on bus-1 is lesser than a programmable value (30%-80% of the rated voltage).
Output relay can be operated either in continuous mode or pulse mode. In continuous mode, the relay N/O contacts operate after a programmable delay and will remain in that condition until either a synchro check fails or h/w or power on reset occurs. In the pulse mode, the relay N/O contacts operate for a short while and gets released after a fixed delay of 150msec.
Ratings
Settings
Over Load Rating
Burden
Accuracy
Voltage rating (Un ):
110V AC
63.5V AC
63.5V AC
Frequency rating :
50Hz
Aux. Supply :
20 – 60V DC
75 - 150V AC /DC
175 – 300V DC or 185 – 250V AC
75 - 150V AC /DC
175 – 300V DC or 185 – 250V AC
Min voltage 1 :
10 to 100% of Un in steps of 1%
Min voltage 2 :
10 to 100% of Un in steps of 1%
Voltage Diff. :
2 to 70% of Un in steps of 1%
Frequency Diff. :
0.02 to 0.2 Hz in steps of 0.01Hz
Phase angle Diff :
5º to 75º in steps of 1º
Dead Bus Voltage :
30 to 80% of Un in steps of 1%
Time Delay :
0.2 to 1.0 sec in steps of 0.1sec
DB/DL closing delay :
2 to 20 sec in steps of 1 sec
Voltage 1 & Voltage 2 :
200% of rated voltage (continuous) to both V1 & V2
AC voltage input :
Less than 0.1VA at Un
Aux. Supply :
Less than 4W (Non Operated) Less than 8W (Operated)
Voltage :
±5%
Frequency :
±0.02Hz
Phase Angle :
±2%
Operating time :
±5%
Contact Ratings
Contact Durability
Mechanical Design
Standard Compliance
Trip / Alarm :
10A at 24V DC / 230V AC
Loaded contact :
10,000 operations min.
Unloaded contact :
100,000 operations min.
Weight :
5000 gms. (approx)
Case Size :
152X296 sq mm, depth 250mm
Installation :
Flush mounting
Panel cutout :
146 x 264 mm
Accuracy Test :
IEC 60255-3
Insulation Test :
IEC 60255-5
TERMINAL DIAGRAM
Ordering Information
Relay type :
JNF 060
Voltage rating :
110V or 63.5V
Aux. Supply :
20 – 60V DC
75 - 150V AC /DC
175 – 300V DC or 185 – 250V AC
75 - 150V AC /DC
175 – 300V DC or 185 – 250V AC