Instantaneous / Definite Time, Battery Earth Fault Relays
₹11,511.50
Product Code: JRC 082
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 7013 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Instantaneous / Definite time
- Wide range of battery voltage
- Solid state reliability
Application
The relay monitor the battery and ensure that no leakage between battery and ground in DC systems.
PRINCIPLE OF OPERATION
The relay measures the leakage current between the battery and earth. If the current exceeds the set value, the relay trips after the time delay setting . The relay output contacts are hand reset
type. Trip test facility is provided to check the relay operation.
Ratings
SETTINGS
Operating Time
BURDEN
ACCURACY
Battery voltage rating :
30V, 48V, 50V, 110V, 220V, 250V DC
Aux. Supply :
230V AC
Current setting :
1 to 8mA in steps of 1mA
Instantaneous :
< 60ms
Definite Time :
0.1 to 1.5s in steps of 0.1s
Battery supply :
10W (maximum)
Auxiliary supply :
Less than 8W (Non operated)
Less than 10W (Operated)
Less than 10W (Operated)
Operating value :
±5%
Operating Time :
±5% or ±30ms whichever is higher
CONTACT RATINGS
Contact Durability
Mechanical Design
STANDARD COMPLIANCE
Trip / Alarm :
10A at 24V DC / 230V AC
Loaded contact :
10,000 operations min.
Unloaded contacts :
100,000 operations min.
Weight :
Approx. 1500 gms
Case size :
144sqmm with a depth of 117mm
Installation :
Flush mounting
Panel cutout :
138mm x 138mm
Accuracy Test :
IEC 60255-3
Insulation Test :
IEC 60255-5
TERMINAL DIAGRAM
Ordering Information
Battery voltage rating:
30V, 48V, 50V, 110V, 220V, 250V DC
Aux. Supply :
230V AC, 50Hz