Two Stage, Neutral Displacement Relay
₹13,048.75
Product Code: JRV 064
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 8271 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Software based design
- Instantaneous/ Definite time selection
- Insensitive to voltages at third harmonic frequencies
- Wide setting range
- Wide auxiliary range
APPLICATION
Neutral Displacement Relay is used for protection of motors, generators and capacitor banks.
PRINCIPLE OF OPERATION
NDR is a voltage operated relay and get's sensing voltage from open delta secondary of potential transformer.
Whenever there is a ground fault in one phase, the voltage in other two phases will rise and generate a sensing voltage which is continuously monitored in the relay. When this voltage exceeds the set value the internal relay operates. The Relay contacts can be used for Alarm & Trip purpose.
The Relay contacts are self reset type and indications are latched. The RESET button provided on the front of relay to clear these latched indications. The TEST button is provided to test the relay contacts for the trip and alarm circuits.
Ratings
Settings
Over Load Ratings
Burden
Accuracy
Voltage rating :
63.5V/ 110V AC
Aux. Supply :
20 to 60V DC
75 to 150V DC
175 to 300V DC / 185-250V AC
75 to 150V DC
175 to 300V DC / 185-250V AC
Voltage setting
Setting range (for Stage 1 and 2 :
Setting range (for Stage 1 and 2 :
2.5% to 80% in steps of 2.5%
Definite time
Setting range (for Stage 1 and 2:
Setting range (for Stage 1 and 2:
0 to 25sec in steps of 0.1sec
Voltage input :
2 times rated continuous
Voltage input :
Less than 2VA at rated
Auxiliary supply :
Less than 2W( Non operated)
Less than 5W(Operated)
Less than 5W(Operated)
Operating value :
+/- 5%
Operating time :
+/- 5% or +/- 30msec
Instantaneous time :
Less than 40millisec
Drop-off to pick up ratio :
80% to 95%
Contact Ratings
Contact Durability
Insulation
STANDARD COMPLIANCEM
Ratings :
10A at 24V DC / 230V AC
Unloaded contact :
1,00,000 operations
Loaded conatct :
10,000 operations
- 2 KV RMS,50 Hz for 1 minute/2.5KV for 1s.
Between all terminals and case - 1 KV RMS, 50 Hz for 1 minute across open contacts as per IEC 60255
Weight :
Approx. 1500 gms
Size :
144 sq mm with depth of 232 mm
Installation :
Flush mounting
Panel cutout :
138mm x 138mm
Accuracy test :
IEC 60255-151
Insulation test :
IEC 60255-27
TERMINAL DIAGRAM
Ordering Information
Voltage rating :
63.5V/ 110V AC
Relay Type :
JRV 064 (Two Stage NDR)
Auxiliary Supply :
1)20V to 60V DC
2)75V to 150V AC/DC
3)175V to 300V DC / 185V to 250V AC
2)75V to 150V AC/DC
3)175V to 300V DC / 185V to 250V AC