3 Phase, Vt Fuse Failure Relay
₹8,098.09
Product Code: JRV 123
Time line :Products will be shipped within 3 weeks from the date of order
Stock In Stock
Viewed 7335 times
Categories
Cart
Account
Search
Recent View
All Categories
×
-
Products Category
- Earth Leakage Relays
- Electromechanical Auxiliary & High Speed Tripping Relays
- Electronic Hooters
- LED Indicating Lamps
- LED Semaphore Indicators
- Micro Processor Based Directional / Non-directional, Non-Communicable Current Relays
- MICRO PROCESSOR BASED INSTANTANEOUS / DEFINITE TIME AC VOLTAGE RELAYS
- Micro Processor Based Multi Shot, Auto Reclose Relays
- Micro Processor Based Neutral Earth Resistor Monitoring Relays
- Micro Processor Based PT Fuse Failure Relays
- MICRO PROCESSOR BASED RESTRICTED E/F RELAYS
- Micro Processor Based Trip Circuit Supervision Relays
- Numerical Check Synchronizing Relays
- Numerical Directional / Non-directional, Non-Communicable Current Relays
- Numerical Non-directional Inverse Time Current Relays Without Communication
- NUMERICAL OVERFLUX RELAYS
- Numerical Transformer Differential Relays
- Panel Accessories
- Push Buttons
- Semaphore Indicators
- Terminal Blocks & Plugs for Testing
- Time Delay Relays
- Two Stage Frequency Relays
- Micro Processor Based Inverse Time Non- Directional, Non-communicable Current Relays
- Non-directional Inverse Time Current Relays With/without Communication
- Micro Processor Based Inverse Time Non-directional, Non-communicable Current Relays
- Micro Processor Based Instantaneous / Definite Time Ac Voltage Relays
- Micro Processor Based Instantaneous / Definite Time Battery E/F Relays
- Micro Processor Based Instantaneous / Definite Time Current Relays
- Micro Processor Based Instantaneous / Definite Time Dc Voltage Relays
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Features
- Solid state reliability
- High speed operation
- Very high load impedance operation
APPLICATION
The relay monitors the healthiness of PT fuses.
PRINCIPLE OF OPERATION
The relay consists of sensing the voltage across each of the fuses separately. In normal condition, the potential across the fuses is nearly zero. On opening out of the fuse the potential across the particular fuse goes up. This potential drives current through the LED of the opto-coupler. The opto-coupler gets switched on due to the current in the opto-coupler provides circuit path for external LED indication and as well for the electromagnetic relay. The sensing circuit comprising of the opto-coupler and the associated driving circuit is separate for each phase. However, the electromagnetic relay providing potential free contacts for alarm and control is common for all the 3 phases.
Ratings
OVER LOAD RATINGS
Burden
Rated voltage :
110V AC,50Hz. 3 phase
Operating time :
Less than 40 milli seconds between the opening of fuse and closing of the open contact of electromagnetic relay
Auxiliary supply :
20 to 60V DC
75 to 150V AC/DC
175 to 300V DC / 185 to 250V AC
75 to 150V AC/DC
175 to 300V DC / 185 to 250V AC
Voltage :
120% of rated voltage continuously
Input voltage :
4 VA (maximum) at 110 V AC with zero load impedence
Auxiliary supply :
Less than 3W(Non operated)
Less than 6W(Operated)
Less than 6W(Operated)
Contact Ratings
Insulation
Rating :
10A at 24V DC/230V AC
- 2KV RMS, 50 Hz for 1 minute/ 2.5KV FOR 1 sec. Between all terminals and cases
- 1KV RMS, 50 Hz for 1 minute across open terminals
Weight :
Less than 2500 gms
Case Size :
144 sq mm(W x H) with depth of 117 mm
Installation :
Flush mounting
Panel cutout :
138 X 138 sq mm(W x H)
TERMINAL DIAGRAM
Ordering Information
Voltage rating :
110V AC, 50Hz. 3Phase
Relay Type :
JRV 123
Auxiliary supply :
20 to 60V DC
75 to 150V AC/DC
175 to 300V DC/ 185 to 250V AC
75 to 150V AC/DC
175 to 300V DC/ 185 to 250V AC